Application · Turbidity measurement

Filter Breakthrough Detection with Inline Turbidity

A filter works quietly until it breaks through. Then particles and suspended solids pass into your product and downstream equipment. An inline turbidity sensor directly after the filter detects the breakthrough the moment it happens, not at the next sample.

FILTER OUTLETLimitTurbidity in the filter outletFilterkieselguhr, candle, membraneTurbidity sensorinline in the outletBreakthrough → turbidity rises → alarm

Inline measurement without sampling

Readings in NTU, FTU, EBC or ppm

Calibration interval typically up to 24 months

Applications

Where filtration monitoring matters

Breweries

Filtration monitoring in brewing and centrifuge inlet and outlet, measured in EBC, for example.

Beverages and food

Filtration in beverage and food production, with dead-space-free cells certified for food applications.

Water treatment

Drinking water and well water treatment, at filter inlet and outlet.

Chemicals and petrochemicals

Filtration and product separation, for example at centrifuge inlet and outlet.

Risk

What an unnoticed breakthrough costs

Product

Hazy or contaminated product has to be reprocessed or discarded.

Downstream equipment

Downstream equipment such as membranes or heat exchangers gets fouled.

Quality

In beverages and food, complaints and quality deviations follow.

Monitoring

Why inline instead of grab samples

A breakthrough often happens suddenly, for example when the filter cake cracks or a membrane fails. A lab sample shows it only after the product has moved on.

An inline turbidity analyzer delivers a continuous reading. A limit value triggers an alarm immediately, for example to switch to recirculation or a standby filter. A slowly rising trend can also point to an exhausted filter early on.

instant

alarm at the limit, for example switch to recirculation

trend

makes gradual changes visible

0–0.5 ppm

smallest typical measuring range of the MoniTurb-C-F

12° FORWARD SCATTERINGLIGHT12°Scattered 12°Transmitted 0°Measuring cell with particlesScattered / transmitted light = turbidity value

Measuring principle

12° forward scattering: how the sensor measures after the filter

After a filter, the product is almost clear. Scattered light measurement is designed for such low to moderate particle concentrations: a focused light beam passes through the medium, and suspended particles scatter part of it. A detector at an angle of 12° captures this forward-scattered light. The more particles in the medium, the stronger the signal.

Calibration is done in the unit you work with: NTU, FTU, EBC or ppm. More on methods and units: Turbidity Measurement in the Process.

12° forward scattering No sampling NTU · FTU · EBC · ppm

Ratio method

Stable despite color and fouling

With the ratio method, the transmitted light is also captured as a reference, and a ratio of scattered and transmitted light is formed.

This largely compensates for product color, lamp aging and light fouling of the optics. Typical calibration and maintenance intervals are up to 24 months.

View turbidity systems

Ratio method

Scattered light
——————
Transmitted light

= turbidity value

More particles mean more scattered light. Color, fouling and lamp aging are largely compensated by the ratio.

Sensors

Suitable sensors

TURBIsmart-F

12° forward scattering, for beverages, brewing and filtration monitoring, among others. Installed in dead-space-free TH-Variline cells certified for food applications. DN 25 to DN 125, up to 120 °C (140 °C short-term), CIP-compatible. Calibration and maintenance interval typically approx. 24 months, NIR LED approx. 5 years. View the TURBIsmart-F

MoniTurb-C-F

12° forward scattering for process lines up to 16 bar and 140 °C, DN 25 to DN 150. Typical measuring ranges 0–0.5 ppm and 0–8,000 ppm, optional cleaning probe, ATEX Zone 1 / Zone 2 optional. View the MoniTurb-C-F

MoniTurb-C-FS

Combines 12° and 90° scattered light: 90° is particularly sensitive to small, finely dispersed particles, while larger particles weigh more strongly at 12°. Comparing both gives an indication of the particle size distribution, for example at filter inlet and outlet in drinking water treatment. View the MoniTurb-C-FS

Installation

Installation and operation

The right sensor depends on medium, hygiene requirements, pressure and temperature. We clarify this in the requirements analysis.

Measuring point

Directly in the filter outlet, as close to the filter as possible, so a breakthrough shows immediately.

Comparison

A second measuring point at the filter inlet shows how well the filter performs.

Response

Reading and limit contacts go to your control system, which can switch to recirculation or bring a standby filter online, for example.

Cleaning

TURBIsmart-F and MoniTurb-C-F are CIP-compatible, and an optional cleaning probe is available for the MoniTurb-C-F.

Working together

Four steps to filter monitoring

We support you from the first question to commissioning.

01

Contact

You describe your application by phone or email.

02

Requirements analysis

We review medium, filter and installation point and recommend the right sensor.

03

Customization

We configure measuring cell, materials, process connection and calibration for your application.

04

Installation

On request, our technicians support installation and commissioning and connect the system to your controls.

FAQ

Frequently asked questions about filter monitoring

Which unit do the sensors measure in?

In the unit of your process: NTU, FTU, EBC or ppm. Calibration is application-specific.

Does product color affect the reading?

The ratio of scattered and transmitted light largely compensates for color.

How often does the sensor need calibration?

The typical calibration and maintenance interval is about 24 months, depending on range and application.

Can I measure before and after the filter?

Yes. Two measuring points show filter performance and reveal a breakthrough at the outlet immediately.

Are hygienic versions available?

Yes. The TURBIsmart-F is installed in dead-space-free measuring cells certified for food applications.